Similar Posts
an incineration / pyrolysis plant budgetary cost
It will always be our preference that the client pre-incinerates / use of pyrolysis (conditions) the raw e-Waste (printed circuit boards, computer memory etc.) which will allow our plasma smelting furnace to treat a concentrated waste, but increasingly, we are being asked to provide a complete turnkey plant including pre-incineration / pyrolysis of the e-waste. We require indicative information and a budgetary cost please for an incineration / pyrolysis plant that will handle about 3000 tonnes per year of raw E-waste producing about 2000 tonnes per year of Integrated Circuit (IC) Sweeps. Here we assume about a 30 – 35% weight loss due to the removal of volatiles. Charging waste. Close the door. Obtaining the combustion cycle during which no monitoring service ( duration 2 hours ) is required. The combustion cycle automatically ensures : Starting the secondary air fan. After 10 minutes, the afterburner is temperature: ?Turning on the automatic burner combustion chamber , which guarantees the output of the gasification of waste. The operating time of the burner is programmable according to the type of waste, using an adjustable mechanical timer from 1-60 minutes. Automatic start of combustion air fan. After 2 hours , the end of ” combustion cycle ” automatically guarantee : The closure of primary air servomotor . The post-combustion burner off. During charging , opening the door automatically ensures immediate shutdown fan primary and secondary air . At the end of the combustion cycle the fan primary / secondary air and burner continues to run for 2 hours to protect the burners and to cool the oven . After this time the program automatically turns off the installation completely . FUEL USE Ideally, we would like the supplied information to cover material loading/unloading, the incineration / pyrolysis process and the off-gas system (scrubbers etc.). Our understanding is that pre-incineration is conducted to homogenise the waste and to minimise the subsequent losses of species at the smelting stage through the formation of chloride/bromide salts and through oxidation losses, i.e. the halogens being driven off at a lower temperature to that at which the salts/oxides could boil in the smelting stage.
MEDICAL WASTE INCINERATOR (50 C 60kg/hr)
Medical Waste Incinerator, 50 to 60 Kg/hrSupport Health Sector Support ProjectPoint of Installation (Hospitals) Moi Voi, Makindu, Maragua, Eldama Ravine and Isiolo District Hospitals1. General DescriptionSupply, delivery, installation and commissioning of a medical waste incinerator suitable for disposal of Medical, General and Pathological waste in a safe and clean environment. The unit shall consist of two chambers and operate on the principal of controlled air and temperature. The unit shall consist a particulate remover (scrubbers) as stipulated in waste management regulations, 2006 (Legal notice NO. 121 of 29th September, 2006). The Unit shall be fully automatic and controlled by an automatic electronic controlled system except loading system which shall be manual. The unit shall be capable of incinerating between 50 to 60 kg of solid medical waste per hour. It shall be constructed from mild or aluminized steel lined with refractory material.Main unit Application For incineration, general and pathologicalCapacity 50 C 60 kg/h burn rateType Two combustion chambers type; primary and Secondary, controlled/forced combustion air type with a flue gas emission scrubbing unitOperating time Minimum 8 hours dailyOperating temperature From 850 0C to 1200 0C, Automatic controlledResidual Ash 5 to 10% 3.2 Primary ChamberConstruction Constructed from heavy duty mild or aluminized steel Orequal and approved equivalentInsulation material Refractory material lining similar or equal to calcium Silicate and hot face combination of heavy duty brickworkInternal Construction Fixed hearth type complete with gratings, concave bottomand charging door, lined with refractory materialCharging Door Suitable for manual loading of wastes and with smooth Dear seal equivalent of Ceramic seals with hinges.Door Lock Automatic, Electric typeAsh removal door Provided, for removing resultant bottom ash leftovers from the Primary chamberGratings ProvidedLoading Manual loading of wastePrimary Burner Fully automatic, with fuel, temperature and speed controls with ignition system, flame detector, Air fan complete with safety features, flame failure, Diesel fired fuel injector type and Flange mounted Blower Provided. For supplying excess combustion air through the distribution system with speed control systemTemperature Minimum exit 850 0CObservation port To be provided with protective glass typeConstruction Constructed from heavy duty mild or aluminized steel or equal and approved equivalentInsulation Refractory material liningCombustion Temperatures Above 850 0C, controlled electronicallyGas residue or retention Time > 2 second at minimum 850 0CSecondary Burner Provided, Diesel fired, fully automatic, with fuel, temperature and speed controls, With ignition system, Flame detector, Air fan, Complete with safety features, flame failure Diesel fired fuel injector type. Flange mountedEjector Provided, Venturi type, for cooling the flue gasesCombustion Air Fan Provided for supplying combustion and creating a negative drift and turbulencesTemperature Maximum 1600 0C
Medical Waste Incinerator Diesel Oil/ Natural Gas/LPG
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/ Email: [email protected]: [email protected] Nanjing Clover Medical Technology Co.,Ltd. Medical waste incineration involves the burning of wastes produced by hospitals, veterinary facilities, and medical research facilities. These wastes include both infectious (“red bag”) medical wastes as well as non-infectious, general housekeeping wastes. Model YD-100 Picture Burning Rate Average 100 kgs/hour Feed Capacity Average 240 kgs/feeding Primary Combustion Chamber…
KN95 Melt Blown Breathing mask machine
Zhangjiagang Tengxiang Machinery Co., Ltd. Mobile: 0086-13962221749(whatsapp) Wechat: chncheumg Email: [email protected] Face Mask Machine for Coronavirus Disease COVID-19 Semi-Automatic Mask Machine l Power supply: 3.3KW mono phase l Mask Size: 175mm*80-100mm (two or three layers) l Nonwoven (GMS): 10-50g l Capacity: 120 to 150pcs/min l Dimension(L*W*H):3800mm*500mm*1400mm l Net Weight: about 1000kg Welding Machine l Capacity: 5 to 10pcs/min l Power supply: 8.5KW mono phase l Compressed Air…
HICLOVER Mobile Containerized Incinerators
a. be based on common, well-proven and clean technology – both as a complete unit and in terms of its individual components. b. be very robust, sturdy and capable of installation in remote locations subject to severe conditions. d. generate residual incinerator ash conforming to <10% by volume and <25% by weight of the waste…
Supply, Installation and Commissioning of DIESEL FIRED INCINERATORS
Supply, Installation and Commissioning of DIESEL FIRED INCINERATORSMedical Waste Incinerator, 100 to 120 Kg/hrApplication For incineration, general and pathologicalCapacity 100 C 120 kg/h burn rateType Two combustion chambers type; primary and Secondary, controlled/forced combustion air type with a flue gas emission scrubbing unitOperating time Minimum 8 hours dailyOperating temperature From 850 0C to 1200 0C, Automatic controlledResidual Ash 5 to 10%Construction Constructed from heavy duty mild or aluminized steelOr equal and approved equivalent Insulation material Refractory material lining similar or equal to calcium Silicate and hot face combination of heavy duty brickworkInternal Construction Fixed hearth type complete with gratings, concave bottom and charging door, lined with refractory materialCharging Door Suitable for manual loading of wastes and with smooth Dear seal equivalent of Ceramic seals with hinges.Door Lock Automatic, Electric typeAsh removal door Provided, for removing resultant bottom ash leftovers from the Primary chamberGratings ProvidedLoading Manual loading of wastePrimary Burner Fully automatic, with fuel, temperature and speed controls with ignition system flame detector Air fan Complete with safety features, flame failure Diesel fired fuel injector type Flange mountedBlower Provided. 3 phase for supplying excess combustion air through the distribution system with speed control systemTemperature Minimum exit 850 0CObservation port To be provided with protective glass type 3.3 Secondary chamber
